Add initial MQTT scrubber service scaffold
This commit is contained in:
@@ -0,0 +1,110 @@
|
||||
package pipeline
|
||||
|
||||
import (
|
||||
"context"
|
||||
"sync"
|
||||
"testing"
|
||||
"time"
|
||||
|
||||
"mqqt-scrubber/internal/config"
|
||||
"mqqt-scrubber/internal/model"
|
||||
)
|
||||
|
||||
type fakeWriter struct {
|
||||
mu sync.Mutex
|
||||
batches [][]model.Record
|
||||
flushed chan struct{}
|
||||
}
|
||||
|
||||
func newFakeWriter() *fakeWriter {
|
||||
return &fakeWriter{flushed: make(chan struct{}, 1)}
|
||||
}
|
||||
|
||||
func (writer *fakeWriter) Write(_ context.Context, records []model.Record) error {
|
||||
writer.mu.Lock()
|
||||
copyBatch := append([]model.Record(nil), records...)
|
||||
writer.batches = append(writer.batches, copyBatch)
|
||||
writer.mu.Unlock()
|
||||
|
||||
select {
|
||||
case writer.flushed <- struct{}{}:
|
||||
default:
|
||||
}
|
||||
|
||||
return nil
|
||||
}
|
||||
|
||||
func (writer *fakeWriter) firstBatch() []model.Record {
|
||||
writer.mu.Lock()
|
||||
defer writer.mu.Unlock()
|
||||
if len(writer.batches) == 0 {
|
||||
return nil
|
||||
}
|
||||
return writer.batches[0]
|
||||
}
|
||||
|
||||
func TestServiceFlushesParsedRecords(t *testing.T) {
|
||||
fake := newFakeWriter()
|
||||
service := NewService(config.Config{
|
||||
App: config.AppConfig{
|
||||
BatchSize: 2,
|
||||
BufferSize: 8,
|
||||
FlushInterval: config.DurationValue{Duration: time.Hour},
|
||||
FlushTimeout: config.DurationValue{Duration: time.Second},
|
||||
},
|
||||
}, fake)
|
||||
|
||||
ctx, cancel := context.WithCancel(context.Background())
|
||||
defer cancel()
|
||||
|
||||
errCh := make(chan error, 1)
|
||||
go func() {
|
||||
errCh <- service.Run(ctx)
|
||||
}()
|
||||
|
||||
service.Enqueue(model.RawMessage{
|
||||
Topic: "tele/tasmota_896001/LWT",
|
||||
Payload: []byte("Online"),
|
||||
ReceivedAt: time.Date(2026, time.March, 12, 15, 21, 39, 0, time.UTC),
|
||||
})
|
||||
service.Enqueue(model.RawMessage{
|
||||
Topic: "tele/tasmota_C88994/SENSOR",
|
||||
Payload: []byte(`{"Time":"2026-03-12T16:23:13","ENERGY":{"TotalStartTime":"2026-02-04T19:13:40","Total":41.385,"Yesterday":1.124,"Today":0.799,"Period":0,"Power":1,"ApparentPower":4,"ReactivePower":4,"Factor":0.22,"Voltage":231,"Current":0.016}}`),
|
||||
ReceivedAt: time.Date(2026, time.March, 12, 16, 23, 13, 0, time.UTC),
|
||||
})
|
||||
|
||||
select {
|
||||
case <-fake.flushed:
|
||||
case <-time.After(2 * time.Second):
|
||||
t.Fatal("timed out waiting for pipeline flush")
|
||||
}
|
||||
|
||||
batch := fake.firstBatch()
|
||||
if len(batch) != 2 {
|
||||
t.Fatalf("expected 2 records in flushed batch, got %d", len(batch))
|
||||
}
|
||||
|
||||
if batch[0].Measurement != "tasmota_lwt" {
|
||||
t.Fatalf("unexpected first measurement: %s", batch[0].Measurement)
|
||||
}
|
||||
if batch[0].Fields["online"] != true {
|
||||
t.Fatalf("unexpected lwt online field: %#v", batch[0].Fields["online"])
|
||||
}
|
||||
|
||||
if batch[1].Measurement != "tasmota_sensor" {
|
||||
t.Fatalf("unexpected second measurement: %s", batch[1].Measurement)
|
||||
}
|
||||
if batch[1].Fields["energy_total"] != float64(41.385) {
|
||||
t.Fatalf("unexpected sensor energy_total field: %#v", batch[1].Fields["energy_total"])
|
||||
}
|
||||
|
||||
cancel()
|
||||
select {
|
||||
case err := <-errCh:
|
||||
if err != nil {
|
||||
t.Fatalf("service returned error: %v", err)
|
||||
}
|
||||
case <-time.After(2 * time.Second):
|
||||
t.Fatal("timed out waiting for service shutdown")
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user